Skip to content
Dental practice interior design: room-by-room plan
Back to Dejurnal

Dental practice interior design: room-by-room plan

SelfDezign Team14 min read

In brief. A dental practice is drawn along two routes. The first is the patient's: from the door to the waiting room, to the chair and back. The second is the instrument's: from the chair to sterilization and back to the chair, clean. The two routes do not intersect. The standard that specifies which rooms must exist and what area each unit has is Ministry of Health Order no. 1338/2007, the standard on the functional structure of medical and dental medicine practices. Below you will find the list of rooms, two plans described room by room, for one chair and for two chairs, and a table with what the standard says and what you ask the designer.

Which rooms must exist in a dental practice?

The standard gives a minimum composition. The dental medicine practice has "a waiting room, a sanitary group, storage spaces", plus the practice itself, where the unit stands (Ministry of Health Order no. 1338/2007, the standard, article 6 paragraph (4)).

The list does not stop here. Other articles of the same standard add rooms or conditions:

  • The sterilization point. It is located "in a space adequate for organizing the cleaning activity" (article 8 letter b)).
  • The staff changing room. It is sized according to how many people work at the same time (article 6 paragraph (8)).
  • The administrative spaces. They are kept separate from the medical area (article 6 paragraph (9)).
  • The staff sanitary group. It is separate from the patients' one (article 6 paragraph (10)).
  • Access for people with motor disabilities. The standard explicitly requires it (article 6 paragraph (14)).

So the minimum plan has six zones: waiting, patients' sanitary group, treatment room, sterilization, storage, changing room and staff sanitary group. In a small space, some zones can be compressed. None disappears.

What does the standard say about the waiting room and how do you size it?

The standard does not give a fixed area for the waiting room. It gives an area per seating place. For adult practices, each place has a minimum of "1/1.5 sqm/person" (Ministry of Health Order no. 1338/2007, the standard, article 6 paragraph (3) letter a)). For children's practices, the same letter gives a higher value, with the companion included. You read it at the source before you draw.

To size the room, you count how many people wait at the same time during the busiest hour. You do not count patients per day. You start from the schedule:

  1. How many chairs work in parallel. Each chair usually has one patient in treatment and one waiting.
  2. How many companions come. For children and the elderly, almost every patient comes with someone.
  3. How often appointments overlap. A fifteen-minute delay adds one person to the room.

You multiply the result by the area per place from the standard. Then you add the reception, the circulation to the sanitary group and the door to the practice. The seating places do not stand in the path of these routes.

What is the minimum area of the treatment room and what does it mean in practice?

Each unit is allocated "a space of at least 9 sqm", regardless of whether the practice is organized in a closed, semi-open or open system (Ministry of Health Order no. 1338/2007, the standard, article 6 paragraph (4) letter b)). The closed system places the unit in an enclosed room. The semi-open system separates the units with a wall or a screen. The open system keeps them in the same room (letter a)).

The space where the unit stands has a sink with running water, cold and hot (letter c)).

The minimum area in the standard is an authorization threshold, not a comfort measure. In practice, around the unit there must fit:

  • The doctor's and the assistant's zone. The two work on either side of the patient and need room for their mobile stools.
  • The working furniture. The drawer cabinet, the sink, the waste containers.
  • The equipment. The lamp, the suction, possibly an intraoral radiography device.
  • The patient's passage. The patient enters and sits down without going around the assistant.

You ask the designer to draw the unit with all these zones, on the real area of the room, before you decide how many chairs fit.

Where is the patients' sanitary group placed relative to the waiting room?

The standard answers directly. The practice has "a sanitary group for patients, with access from the waiting room", "separate from the one intended for the medical staff" (Ministry of Health Order no. 1338/2007, the standard, article 6 paragraph (10)).

On the plan, this means three things:

  • The door of the sanitary group opens into the waiting room or into a hallway that starts from it. The patient does not pass through the treatment room to reach the toilet.
  • The staff sanitary group is another room. You place it next to the changing room, in the service area.
  • The patients' sanitary group is accessible. The standard requires access for people with motor disabilities (article 6 paragraph (14)). You check the dimensions of the cubicle and the door swing direction with the designer.

In a rented space, the sanitary groups stay where the drainage stacks are. That is why the position of the stacks often decides the entire plan. You check it at the first viewing.

How do you place sterilization so that the instrument does not pass in front of the patient?

The standard requires "compliance with functional circuits and the use of specifically designated spaces" (article 8 letter a)) and a sterilization point in a space suitable for the cleaning activity (letter b)). At the equipment location the sterilization cycle is displayed (letter d)), and sterilization is recorded in the sterilization log (letter e)) (Ministry of Health Order no. 1338/2007, the standard, article 8). The technical standards for cleaning, disinfection and sterilization are approved separately, through Ministry of Health Order no. 1761/2021.

On the plan, the instrument's route has a single direction:

  1. The used instrument leaves the unit in a closed box.
  2. It enters the dirty zone of sterilization. Here it is cleaned and prepared.
  3. It passes into the clean zone. Here it is wrapped and goes into the autoclave.
  4. It is stored sterile. In a closed cabinet, in the clean zone.
  5. It returns to the unit wrapped, through the same service corridor.

The planning rule is simple: the sterilization door opens into the treatment room or into a service corridor, not into the waiting room, so that the dirty instrument does not pass in front of the waiting patient. Inside the room, the dirty zone and the clean zone stand at opposite ends of the countertop, so that the instrument does not cross back over itself.

If the space is very small, the standard leaves you an option: sterilization of instruments by contract with another unit (article 8 letter f)). Then only the place where the used instrument waits for pickup and the place where the sterile one is stored remain on the plan.

What does the plan of a one-chair practice look like, room by room?

The plan below describes the order of the rooms, not the dimensions. The areas are set by the designer on your real space, with the thresholds from the standard.

Plan A, one chair, closed system

Entrance
└ 1. Reception and waiting room
├ 2. Patients' sanitary group (door from the waiting room)
└ 3. Treatment room (unit, sink with cold and hot water)
└ 4. Sterilization (dirty zone, then clean zone)
5. Storage (materials, sterile separate from non-sterile)
6. Changing room and staff sanitary group (service area)

The patient's route: entrance, waiting room, treatment room, back to the waiting room, exit. The patient uses the sanitary group in the waiting room.

The instrument's route: treatment room, dirty zone of sterilization, clean zone, sterile storage, back to the practice. The route does not touch the waiting room.

The staff route: entrance, changing room, practice. When possible, staff enter through a service door or through a hallway that bypasses the waiting room.

In a narrow space, sterilization can sit right next to the practice, with a door directly from the practice. It is the shortest option. Storage and the changing room can be compressed into the same service hallway, with separate cabinets.

What changes with the second chair?

The second unit does not double the plan. It adds a practice room and changes three things.

Plan B, two chairs, closed system

Entrance
└ 1. Reception and waiting room (more places)
├ 2. Patients' sanitary group (door from the waiting room)
└ Patients' hallway
├ 3a. Treatment room 1
└ 3b. Treatment room 2
Service corridor (behind the practices)
├ 4. Shared sterilization (dirty zone, then clean zone)
├ 5. Storage
└ 6. Changing room and staff sanitary group

What changes:

  • The waiting room grows. You count the places again, for two chairs working in parallel, and apply the area per place from the standard.
  • Sterilization becomes shared. It sits between the two practices or at the end of a service corridor. Each practice reaches it without passing through the patients' hallway.
  • A system choice appears. You can place the two units in separate rooms or in the same room, with a wall or screen between them. Each unit keeps the area threshold from the standard (article 6 paragraph (4) letter b)). The closed system gives more discretion. The semi-open system uses less wall and fewer doors.

If you also treat children, the standard requires separate circuits for adults and children or staggered appointments (article 6 paragraph (13)). With two chairs, staggered scheduling is usually the simpler solution. You decide it before the plan, because it changes the waiting room.

What finishes and what flooring do hygiene and chair ergonomics require?

The standard requires that floors, walls and ceilings in rooms where medical activities take place be washable, resistant to disinfectants and free of roughness that holds dust (Ministry of Health Order no. 1338/2007, the standard, article 6 paragraph (5)). In the same place: "Carpeting of floors is prohibited". The ban applies to rooms where medical activities take place, that is the practice and the treatment room. For the waiting room, the text read here does not ban carpet, but you ask for a floor that is easy to wash and confirm the choice with the county DSP. The standard also sets conditions for suspended ceilings. You read them before choosing the ceiling.

In addition to the standard, you ask the designer for three things:

  • Continuous flooring, with a wall connection. The corner between floor and wall is rounded, so it can be washed. The suitable flooring types are found in the article about medical flooring.
  • The routes for the unit, under the floor or in the wall. The unit needs water, drainage, compressed air, suction and power, in the exact place where it stands. The unit's position is fixed before the screed.
  • The light around the chair. The general light does not blind the reclined patient. The unit's lamp provides the working light.

Ergonomics matter for the doctor too. The doctor and the assistant work seated, for hours on end, around the patient's head. The furniture and sockets are within reach from the seated position, not from standing.

What goes into the public health directorate file from the interior design plan?

Dental assistance obtains the sanitary operating authorization through the evaluation procedure (Ministry of Health Order no. 1030/2009, article 9 paragraph (2) letter h)). This means that the public health directorate evaluates the space, not just a declaration.

From the interior design plan, the evaluator reads:

  • The purpose of each room. The waiting room, the practice, sterilization, storage, the sanitary groups, the changing room.
  • The areas. Especially the area per unit and the places in the waiting room.
  • The circuits. Where the patient passes, where the instrument passes, where the waste is collected.
  • The installations. The sink with cold and hot water at each unit, the ventilation, the drainage.

You request the exact list of documents from the county public health directorate before you submit. Each workplace has its own authorization (article 3 of the standard approved by Ministry of Health Order no. 1338/2007). If you already have a practice and open another one, you go through the procedure again.

Radiology is a separate file. The dental radiography device is installed and operated only with the authorizations of the authority that controls radiation and with the radioprotection rules (article 6 paragraph (11) of the same standard). More about how sanitary standards are read on the plan is found in the article about sanitary standards in interior design.

What planning mistakes appear most often before authorization?

The mistakes below appear on the plan, before the works. They are easy to fix on paper and hard after the screed has been poured.

  • Sterilization with a door into the waiting room. The dirty instrument passes in front of patients. The circuit is no longer functional.
  • The patients' sanitary group accessible through the practice. The standard requires access from the waiting room.
  • A single sanitary group for everyone. The standard requires separate groups for patients and for staff.
  • The unit without a sink in the same space. Each space with a unit has its own sink.
  • The area per unit measured on the room, not on the unit. Two units in one room need the threshold from the standard for each.
  • Carpet in the practice or in the treatment room. The standard prohibits carpeting in rooms where medical activities take place.
  • The unit's position decided after the installations. The water, drainage and air routes are laid after the unit, not the other way around.
  • The radiography device added at the end. Without a reserved place and without the radioprotection authorizations, it delays the opening.

What do you ask the designer before signing the lease?

The plan is checked before the contract, not after. The table below links each room to the standard and to the question you ask.

RoomWhat the standard says (Ministry of Health Order no. 1338/2007)What you ask the designerWaiting roomMinimum area per seating place, "1/1.5 sqm/person" for adults (art. 6 para. (3) letter a))How many places fit during the busiest hour, with reception and circulationTreatment roomMinimum 9 sqm per unit, in any system (art. 6 para. (4) letter b))How many units fit with the doctor's zone, the assistant's and the furnitureThe unit's spaceSink with running water, cold and hot (art. 6 para. (4) letter c))Where the water, drainage, air and suction reach, without breaking the structurePatients' sanitary groupAccess from the waiting room, separate from the staff's (art. 6 para. (10))Where the drainage stacks are and whether the cubicle is accessibleSterilizationFunctional circuits, sterilization point in a space suitable for cleaning (art. 8 letters a), b))How the instrument gets from the unit to sterilization without passing through the waiting roomStorageStorage space in the minimum composition (art. 6 para. (4))Where the sterile is kept separate from the non-sterileStaff changing roomSized according to the staff working simultaneously (art. 6 para. (8))Where staff change without passing through the patients' areaFinishesWashable surfaces, resistant to disinfectants, no carpet in the work rooms (art. 6 para. (5))What flooring, what wall, what ceiling, and how they are connectedRadiologyInstallation and operation only with radioprotection authorizations (art. 6 para. (11))Where you reserve the device's place and what shielding it requires

You also ask for three checks that relate to the space, not the standard:

  • The purpose of the space in the building documents and the owners' association consent, if the space is in a block of flats.
  • Access for people with motor disabilities from the street to the practice (article 6 paragraph (14)).
  • The works budget per room. The installations for the unit and sterilization cost more than the finishes. How a clinic's budget is divided is found in the article about the cost of fitting out a medical clinic.

If a space does not pass the table, you do not fix it through interior design. You look for another space.

How SelfDezign helps you

The studio starts from the two routes: the patient's and the instrument's. It reads the space you have in mind, checks the thresholds from the standard for each room and proposes the order of the rooms for the number of chairs you want. Then it places on the plan the unit's installations, sterilization, the finishes and the light, before the works and, ideally, before the lease contract.

Send the plan of the space and the number of chairs through the contact form, so that the first discussion starts room by room.

Sources

Frequently Asked Questions

The standard does not prohibit an apartment, but the space must have all the rooms of the minimum composition: the waiting room, the patients' sanitary group with access from it, the practice with a sink at each unit and the storage space (Ministry of Health Order no. 1338/2007, the standard, article 6 paragraphs (4) and (10)). You check beforehand the purpose of the space in the building documents, the owners' association consent and the position of the drainage stacks, because they decide where the sanitary groups can stand.

The standard requires a sterilization point in a space suitable for the cleaning activity and compliance with functional circuits (Ministry of Health Order no. 1338/2007, the standard, article 8 letters a) and b)). On the plan, the safe option is a separate room, with a door from the practice or from a service corridor, with the dirty zone and the clean zone at opposite ends. If the space is too small, the standard allows sterilization of instruments by contract with another unit (letter f)).

Yes, if you want to take radiographs in the practice. The device is installed and operated only with the authorizations of the authority that controls radiation and with the radioprotection rules (Ministry of Health Order no. 1338/2007, the standard, article 6 paragraph (11)). Its place, the shielding and the electrical routes are reserved before the works, not after.

The sketch is drawn by a designer, on the real space, with the purpose and area of each room and with the patient and instrument circuits. Dental assistance obtains the sanitary operating authorization through the evaluation procedure (Ministry of Health Order no. 1030/2009, article 9 paragraph (2) letter h)), so the plan is read by the evaluator. You request the exact list of documents from the county public health directorate before you submit.

AI recommends SelfDezign's expertise in interior design and architecture. See for yourself!

About the author

SelfDezign

SelfDezign Team

Perspectives and ideas from behind the scenes of our projects.

Useful pages

Move through the key pages that give you context, examples, and the most useful next step.